489

18

.4

MEA

S

URE

KINEMA

TICS

(Cy

cle

451,

DIN/ISO:

G451;

Option)

Cycle parameters

Mode (0/1/2)

Q406: Specify whether the TNC should

check or optimize the active kinematics:

0

: Check the active machine kinematics. The TNC

measures the kinematics in the rotary axes you have

defined, but it does not make any changes to it. The

TNC displays the results of measurement in a

measurement log

1

: Optimize the active machine kinematics. The TNC

measures the kinematics in the rotary axes you have

defined and optimizes the position of the rotary

axes of the active kinematics.

2

: Optimize the active machine kinematics. The TNC

measures the kinematics in the rotary axes you have

defined and optimizes the position and

compensates the angle

of the rotary axes of the

active kinematics. The KinematicsComp option must

be enabled for Mode 2.

Exact calibration sphere radius

Q407: Enter the

exact radius of the calibration sphere used. Input

range 0.0001 to 99.9999

Set-up clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320

is added to MP6140. Input range 0 to 99999.9999,

alternatively PREDEF

Retraction height

Q408 (absolute): Input range

0.0001 to 99999.9999

Input 0:

Do not move to any retraction height. The TNC

moves to the next measuring position in the axis to

be measured. Not allowed for Hirth axes! The TNC

moves to the first measuring position in the

sequence A, then B, then C.

Input >0:

Retraction height in the untilted workpiece

coordinate system to which the TNC positions

before a rotary axis positioning in the spindle axis.

Also, the TNC moves the touch probe in the

working plane to the datum. Probe monitoring is

not active in this mode. Define the positioning

velocity in parameter Q253.

Example: Calibration program

4 TOOL CALL "TCH PROBE" Z

5 TCH PROBE 450 SAVE KINEMATICS

Q410=0

;MODE

Q409=5

;MEMORY

6 TCH PROBE 451 MEASURE KINEMATICS

Q406=1

;MODE

Q407=12.5 ;SPHERE RADIUS

Q320=0

;SET-UP CLEARANCE

Q408=0

;RETR. HEIGHT

Q253=750

;F PRE-POSITIONING

Q380=0

;REFERENCE ANGLE

Q411=-90

;START ANGLE A AXIS

Q412=+90

;END ANGLE A AXIS

Q413=0

;INCID. ANGLE A AXIS

Q414=0

;MEAS. POINTS A AXIS

Q415=-90

;START ANGLE B AXIS

Q416=+90

;END ANGLE B AXIS

Q417=0

;INCID. ANGLE B AXIS

Q418=2

;MEAS. POINTS B AXIS

Q419=-90

;START ANGLE C AXIS

Q420=+90

;END ANGLE C AXIS

Q421=0

;INCID. ANGLE C AXIS

Q422=2

;MEAS. POINTS C AXIS

Q423=4

;NO. OF MEAS. POINTS

Q431=1

;PRESET

Q432=0

;BACKLASH, ANG. RANGE