beautypg.com

Cycle run – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 350

background image

350

Touch probe cycles: automatic measurement of workpiece misalignment

14.7

Compensating

w

o

rk

piece

misalignment

b

y

ro

tating

the

c

axis

(Cy

cle

405,

DIN/ISO:

G405)

14.7 Compensating workpiece

misalignment by rotating the c

axis (Cycle 405, DIN/ISO: G405)

Cycle run

With Touch Probe Cycle 405, you can measure

the angular offset between the positive Y axis of the active

coordinate system and the center of a hole, or

the angular offset between the nominal position and the actual

position of a hole center.

The TNC compensates the determined angular offset by rotating the

C axis. The workpiece can be clamped in any position on the rotary

table, but the Y coordinate of the hole must be positive. If you

measure the angular misalignment of the hole with touch probe axis Y

(horizontal position of the hole), it may be necessary to execute the

cycle more than once because the measuring strategy causes an

inaccuracy of approx. 1% of the misalignment.
1

Following the positioning logic (see "Executing touch probe cycles"

on page 332), the TNC positions the touch probe to the probe

starting point

1

at rapid traverse (value from MP6150). The TNC

calculates the probe starting points from the data in the cycle and

the safety clearance from MP6140.

2

Then the touch probe moves to the entered measuring height and

probes the first touch point at the probing feed rate (MP6120). The

TNC derives the probing direction automatically from the

programmed starting angle.

3

Then the touch probe moves in a circular arc either at measuring

height or at clearance height to the next starting point

2

and probes

the second touch point.

4

The TNC positions the probe to starting point

3

and then to starting

point

4

to probe the third and fourth touch points, and then

positions the touch probe to the center of the measured hole.

5

Finally the TNC returns the touch probe to the clearance height and

aligns the workpiece by rotating the table. The TNC rotates the

rotary table so that the hole center after compensation lies in the

direction of the positive Y axis, or on the nominal position of the

hole center—both with a vertical and horizontal touch probe axis.

The measured angular misalignment is also available in parameter

Q150.

X

Y

1

2

4

3

X

Y

This manual is related to the following products: