16.4 MEA

S

URE ANGLE (Cy

cle 420, DIN/ISO:

G420)

Traverse direction 1

Q267: Direction in which the

probe is to approach the workpiece:

–1

:Negative traverse direction

+1

: Positive traverse direction

Measuring height in the touch probe axis

Q261

(absolute): Coordinate of the ball tip center (= touch

point) in the touch probe axis in which the

measurement is to be made. Input range

-99999.9999 to 99999.9999

Set-up clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320

is added to MP6140. Input range 0 to 99999.9999,

alternatively PREDEF

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch

probe and workpiece (fixtures) can occur. Input range

-99999.9999 to 99999.9999, alternatively PREDEF

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the

measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

Alternatively PREDEF

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:

0

: No measuring log

1

: Generate measuring log: with the standard setting

the TNC saves the log file TCHPR420.TXT in the

directory in which your measuring program is also

stored.

2

: Interrupt program run and display the measuring

log on the screen. Resume program run with NC

Start.

Example: NC blocks

5 TCH PROBE 420 MEASURE ANGLE

Q263=+10

;1ST POINT 1ST AXIS

Q264=+10

;1ST POINT 2ND AXIS

Q265=+15

;2ND POINT 1ST AXIS

Q266=+95

;2ND POINT 2ND AXIS

Q272=1

;MEASURING AXIS

Q267=-1

;TRAVERSE DIRECTION

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+10

;CLEARANCE HEIGHT

Q301=1

;MOVE TO CLEARANCE

Q281=1

;MEASURING LOG

This manual is related to the following products: