HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual
Page 400

400
Touch probe cycles: automatic datum setting
15.12
D
A
TUM
A
T
CENTER
OF
4
HOLES
(Cy
cle
41
8,
DIN/ISO:
G41
8)
Probe in TS axis
Q381: Specify whether the TNC
should also set the datum in the touch probe axis:
0
: Do not set datum in the touch probe axis
1
: Set datum in the touch probe axis
Probe TS axis: Coord. 1st axis
Q382 (absolute):
Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 = 1
Probe TS axis: Coord. 2nd axis
Q383 (absolute):
Coordinate of the probe point in the minor axis of the
working plane at which point the datum is to be set in
the touch probe axis. Only effective if Q381 = 1st
input range -99999.9999 to 99999.9999
Probe TS axis: Coord. 3rd axis
Q384 (absolute):
Coordinate of the probe point in the touch probe axis,
at which point the datum is to be set in the touch
probe axis. Only effective if Q381 = 1st input range
-99999.9999 to 99999.9999
New datum in TS axis
Q333 (absolute): Coordinate in
the touch probe axis at which the TNC should set the
datum. Default setting = 0 input range -99999.9999 to
99999.9999
Example: NC blocks
5 TCH PROBE 418 DATUM FROM 4 HOLES
Q268=+20
;1ST CENTER IN 1ST AXIS
Q269=+25
;1ST CENTER IN 2ND AXIS
Q270=+150 ;2ND CENTER IN 1ST AXIS
Q271=+25
;2ND CENTER IN 2ND AXIS
Q316=+150 ;3RD CENTER IN 1ST AXIS
Q317=+85
;3RD CENTER IN 2ND AXIS
Q318=+22
;4TH CENTER IN 1ST AXIS
Q319=+80
;4TH CENTER IN 2ND AXIS
Q261=-5
;MEASURING HEIGHT
Q260=+10
;CLEARANCE HEIGHT
Q305=12
;NO. IN TABLE
Q331=+0
;DATUM
Q332=+0
;DATUM
Q303=+1
;MEAS. VALUE TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+85
;1ST CO. FOR TS AXIS
Q383=+50
;2ND CO. FOR TS AXIS
Q384=+0
;3RD CO. FOR TS AXIS
Q333=+0
;DATUM