beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 403

background image

HEIDENHAIN iTNC 530

403

15.13

D

A

TUM

IN

ONE

AXIS

(C

yc

le

41

9,

DIN/ISO:

G41

9)

Traverse direction

Q267: Direction in which the

probe is to approach the workpiece:

–1

: Negative traverse direction

+1

: Positive traverse direction

Datum number in table

Q305: Enter the number in the

datum or preset table in which the TNC is to save the

coordinate. If you enter Q305=0, the TNC

automatically sets the display so that the new datum

is on the probed surface. Input range 0 to 2999

New datum

Q333 (absolute): Coordinate at which the

TNC should set the datum. Default setting = 0 input

range -99999.9999 to 99999.9999

Measured-value transfer (0, 1)

Q303: Specify

whether the determined datum is to be saved in the

datum table or in the preset table:

–1

: Do not use. See "Saving the calculated datum" on

page 358

0

: Write determined datum in the active datum table.

The reference system is the active workpiece

coordinate system.

1

: Write determined datum in the preset table. The

reference system is the machine coordinate system

(REF system).

Example: NC blocks

5 TCH PROBE 419 DATUM IN ONE AXIS

Q263=+25

;1ST POINT 1ST AXIS

Q264=+25

;1ST POINT 2ND AXIS

Q261=+25

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+50

;CLEARANCE HEIGHT

Q272=+1

;MEASURING AXIS

Q267=+1

;TRAVERSE DIRECTION

Q305=0

;NO. IN TABLE

Q333=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

This manual is related to the following products: