beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 491

background image

HEIDENHAIN iTNC 530

491

18

.4

MEA

S

URE

KINEMA

TICS

(Cy

cle

451,

DIN/ISO:

G451;

Option)

Start angle C axis

Q419 (absolute): Starting angle in

the C axis at which the first measurement is to be

made. Input range -359.999 to 359.999

End angle C axis

Q420 (absolute): Ending angle in the

C axis at which the last measurement is to be made.

Input range -359.999 to 359.999

Angle of incid. in C axis

Q421: Angle of incidence

in the C axis at which the other rotary axes are to be

measured. Input range -359.999 to 359.999

Number meas. points C axis

Q422: Number of probe

measurements with which the TNC is to measure the

C axis. Input range 0 to 12. If input value = 0, the TNC

does not measure the respective axis.

No. of measuring points

Q423: Specify the number

of probing points to be used by the TNC for

measuring the calibration sphere in the plane. Input

range: 3 to 8 measurements

Preset (0/1/2/3)

Q431: Specify whether the TNC is

to set the active preset (datum) automatically in the

center of the sphere:

0

: Do not set the preset automatically in the center of

the sphere: Set the preset manually before the start

of the cycle

1

: Set the preset automatically in the center of the

sphere before measurement: Pre-position the touch

probe manually over the calibration sphere before the

start of the cycle

2

: Set the preset automatically in the center of the

sphere after measurement: Set the preset manually

before the start of the cycle

3

: Set the preset in the center of the sphere before

and after measurement: Pre-position the touch probe

manually over the calibration sphere before the start

of the cycle

Backlash, angle range

Q432: Here you define the

angle value to be used as traverse for the

measurement of the rotary axis. The traversing angle

must be significantly larger than the actual backlash

of the rotary axes. If input value = 0, the TNC does not

measure the backlash. Input range: -3.0000 to

+3.0000

If you have activated "Preset" before measurement (Q431

= 1/3), then move the touch probe to a position above the

center of the calibration sphere before the start of the

cycle.

This manual is related to the following products: