Touch probe cycles: special functions

17

.5 MEA

S

URING IN 3-D (Cy

cle 4, FCL

3 function)

Cycle parameters

Parameter number for result:

Enter the number of

the Q parameter to which you want the TNC to assign

the first coordinate (X). Input range 0 to 1999

Relative measuring path in X:

X component of the

direction vector defining the direction in which the

touch probe is to move. Input range -99999.9999 to

99999.9999

Relative measuring path in Y:

Y component of the

direction vector defining the direction in which the

touch probe is to move. Input range -99999.9999 to

99999.9999

Relative measuring path in Z:

Z component of the

direction vector defining the direction in which the

touch probe is to move. Input range -99999.9999 to

99999.9999

Maximum measuring path:

Enter the maximum

distance from the starting point by which the touch

probe may move along the direction vector. Input

range -99999.9999 to 99999.9999

Feed rate for measurement

: Enter the measuring

feed rate in mm/min. Input range 0 to 3000.000

Maximum retraction distance:

Traverse path in the

direction opposite the probing direction, after the

stylus was deflected. Input range 0 to 99999.9999

Reference system? (0=ACT/1=REF)

: Specify whether

the result of measurement is to be saved in the actual

coordinate system (ACT, can be shifted or rotated), or

with respect to the machine coordinate system (REF).

0

: Save the measurement result in the ACT system

1

: Save the measurement result in the REF system

Example: NC blocks

5 TCH PROBE 4.0 MEASURING IN 3-D

6 TCH PROBE 4.1 Q1

7 TCH PROBE 4.2 IX-0.5 IY-1 IZ-1

8 TCH PROBE
4.3 DIST +45 F100 MB50 REFERENCE SYSTEM:0