Touch probe cycles: special functions
17
.5 MEA
S
URING IN 3-D (Cy
cle 4, FCL
3 function)
Cycle parameters
Parameter number for result:
Enter the number of
the Q parameter to which you want the TNC to assign
the first coordinate (X). Input range 0 to 1999
Relative measuring path in X:
X component of the
direction vector defining the direction in which the
touch probe is to move. Input range -99999.9999 to
99999.9999
Relative measuring path in Y:
Y component of the
direction vector defining the direction in which the
touch probe is to move. Input range -99999.9999 to
99999.9999
Relative measuring path in Z:
Z component of the
direction vector defining the direction in which the
touch probe is to move. Input range -99999.9999 to
99999.9999
Maximum measuring path:
Enter the maximum
distance from the starting point by which the touch
probe may move along the direction vector. Input
range -99999.9999 to 99999.9999
Feed rate for measurement
: Enter the measuring
feed rate in mm/min. Input range 0 to 3000.000
Maximum retraction distance:
Traverse path in the
direction opposite the probing direction, after the
stylus was deflected. Input range 0 to 99999.9999
Reference system? (0=ACT/1=REF)
: Specify whether
the result of measurement is to be saved in the actual
coordinate system (ACT, can be shifted or rotated), or
with respect to the machine coordinate system (REF).
0
: Save the measurement result in the ACT system
1
: Save the measurement result in the REF system
Example: NC blocks
5 TCH PROBE 4.0 MEASURING IN 3-D
6 TCH PROBE 4.1 Q1
7 TCH PROBE 4.2 IX-0.5 IY-1 IZ-1
8 TCH PROBE
4.3 DIST +45 F100 MB50 REFERENCE SYSTEM:0