beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 376

background image

376

Touch probe cycles: automatic datum setting

15.6 D

A

TUM FR

OM INSIDE OF CIR

C

LE (Cy

cle 412, DIN/ISO:

G412)

Measuring height in the touch probe axis

Q261

(absolute): Coordinate of the ball tip center (= touch

point) in the touch probe axis in which the

measurement is to be made. Input range

-99999.9999 to 99999.9999

Set-up clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320

is added to MP6140. Input range 0 to 99999.9999,

alternatively PREDEF

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch

probe and workpiece (fixtures) can occur. Input range

-99999.9999 to 99999.9999, alternatively PREDEF

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the

measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

Alternatively PREDEF

Datum number in table

Q305: Enter the number in the

datum/preset table in which the TNC is to save the

coordinates of the pocket center. If you enter

Q305=0, the TNC automatically sets the display so

that the new datum is at the center of the pocket.

Input range 0 to 2999

New datum for reference axis

Q331 (absolute):

Coordinate in the reference axis at which the TNC

should set the pocket center. Default setting = 0 input

range -99999.9999 to 99999.9999

New datum for minor axis

Q332 (absolute):

Coordinate in the minor axis at which the TNC should

set the pocket center. Default setting = 0 input range

-99999.9999 to 99999.9999

Measured-value transfer (0, 1)

Q303: Specify

whether the determined datum is to be saved in the

datum table or in the preset table:

–1

: Do not use. Is entered by the TNC when old

programs are read in (see "Saving the calculated

datum" on page 358).

0

: Write determined datum in the active datum table.

The reference system is the active workpiece

coordinate system.

1

: Write determined datum in the preset table. The

reference system is the machine coordinate system

(REF system).

X

Z

Q261

Q260

MP6140

+

Q320

This manual is related to the following products: