beautypg.com

Cycle parameters – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 499

background image

HEIDENHAIN iTNC 530

499

18

.5

PRESET

COMPENSA

TION

(Cy

cle

452,

DIN/ISO:

G452,

Option)

Cycle parameters

Exact calibration sphere radius

Q407: Enter the

exact radius of the calibration sphere used. Input

range 0.0001 to 99.9999

Set-up clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320

is added to MP6140. Input range 0 to 99999.9999,

alternatively PREDEF

Retraction height

Q408 (absolute): Input range

0.0001 to 99999.9999

Input 0:

Do not move to any retraction height. The TNC

moves to the next measuring position in the axis to

be measured. Not allowed for Hirth axes! The TNC

moves to the first measuring position in the

sequence A, then B, then C.

Input >0:

Retraction height in the untilted workpiece

coordinate system to which the TNC positions

before a rotary axis positioning in the spindle axis.

Also, the TNC moves the touch probe in the

working plane to the datum. Probe monitoring is

not active in this mode. Define the positioning

velocity in parameter Q253.

Feed rate for pre-positioning

Q253: Traversing

speed of the tool during positioning in mm/min. Input

range 0.0001 to 99999.9999; alternatively FMAX,
FAUTO

, PREDEF

Reference angle

Q380 (absolute): Reference angle

(basic rotation) for measuring the measuring points in

the active workpiece coordinate system. Defining a

reference angle can considerably enlarge the

measuring range of an axis. Input range 0 to 360.0000

Start angle A axis

Q411 (absolute): Starting angle in

the A axis at which the first measurement is to be

made. Input range -359.999 to 359.999

End angle A axis

Q412 (absolute): Ending angle in the

A axis at which the last measurement is to be made.

Input range -359.999 to 359.999

Angle of incid. A axis

Q413: Angle of incidence in

the A axis at which the other rotary axes are to be

measured. Input range -359.999 to 359.999

Number meas. points A axis

Q414: Number of probe

measurements with which the TNC is to measure the

A axis. If the input value = 0, the TNC does not

measure the respective axis. Input range 0 to 12

Start angle B axis

Q415 (absolute): Starting angle in

the B axis at which the first measurement is to be

made. Input range -359.999 to 359.999

Example: Calibration program

4 TOOL CALL "TCH PROBE" Z

5 TCH PROBE 450 SAVE KINEMATICS

Q410=0

;MODE

Q409=5

;MEMORY

6 TCH PROBE 452 PRESET COMPENSATION

Q407=12.5 ;SPHERE RADIUS

Q320=0

;SET-UP CLEARANCE

Q408=0

;RETR. HEIGHT

Q253=750

;F PRE-POSITIONING

Q380=0

;REFERENCE ANGLE

Q411=-90

;START ANGLE A AXIS

Q412=+90

;END ANGLE A AXIS

Q413=0

;INCID. ANGLE A AXIS

Q414=0

;MEAS. POINTS A AXIS

Q415=-90

;START ANGLE B AXIS

Q416=+90

;END ANGLE B AXIS

Q417=0

;INCID. ANGLE B AXIS

Q418=2

;MEAS. POINTS B AXIS

Q419=-90

;START ANGLE C AXIS

Q420=+90

;END ANGLE C AXIS

Q421=0

;INCID. ANGLE C AXIS

Q422=2

;MEAS. POINTS C AXIS

Q423=4

;NO. OF MEAS. POINTS

Q432=0

;BACKLASH, ANG. RANGE

This manual is related to the following products: