377

15.6 D

A

TUM FR

OM INSIDE OF CIR

C

LE (Cy

cle 412, DIN/ISO:

G412)

Probe in TS axis

Q381: Specify whether the TNC

should also set the datum in the touch probe axis:

0

: Do not set datum in the touch probe axis

1

: Set datum in the touch probe axis

Probe TS axis: Coord. 1st axis

Q382 (absolute):

Coordinate of the probe point in the reference axis of

the working plane at which point the datum is to be

set in the touch probe axis. Only effective if Q381 =

1st input range -99999.9999 to 99999.9999

Probe TS axis: Coord. 2nd axis

Q383 (absolute):

Coordinate of the probe point in the minor axis of the

working plane at which point the datum is to be set in

the touch probe axis. Only effective if Q381 = 1st

input range -99999.9999 to 99999.9999

Probe TS axis: Coord. 3rd axis

Q384 (absolute):

Coordinate of the probe point in the touch probe axis,

at which point the datum is to be set in the touch

probe axis. Only effective if Q381 = 1st input range

-99999.9999 to 99999.9999

New datum in TS axis

Q333 (absolute): Coordinate in

the touch probe axis at which the TNC should set the

datum. Default setting = 0 input range -99999.9999 to

99999.9999

No. of measuring points (4/3)

Q423: Specify

whether the TNC should measure the hole with 4 or

3 probing points:

4

: Use 4 measuring points (standard setting)

3

: Use 3 measuring points

Type of traverse? Line=0/Arc=1

Q365: Definition of

the path function with which the tool is to move

between the measuring points if "traverse to

clearance height" (Q301=1) is active.

0

: Move between operations on a straight line

1

: Move between operations on the pitch circle

Example: NC blocks

5 TCH PROBE 412 DATUM INSIDE CIRCLE

Q321=+50

;CENTER IN 1ST AXIS

Q322=+50

;CENTER IN 2ND AXIS

Q262=75

;NOMINAL DIAMETER

Q325=+0

;STARTING ANGLE

Q247=+60

;STEPPING ANGLE

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q305=12

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM

Q423=4

;NO. OF MEAS. POINTS

Q365=1

;TYPE OF TRAVERSE