HEIDENHAIN iTNC 530

473

17

.8 CALIBRA

TE TS (Cy

cle 460, DIN/ISO:

G460)

Cycle parameters

Exact calibration sphere radius

Q407: Enter the

exact radius of the calibration sphere used. Input

range 0.0001 to 99.9999

Set-up clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320

is added to MP6140. Input range 0 to 99999.9999,

alternatively PREDEF

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the

measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

Alternatively PREDEF

No. of probe points in plane (4/3)

Q423: Specify

whether the TNC should measure the calibration

sphere in the plane with 4 or 3 probing points. Three

probing points increase the measuring speed:

4

: Use 4 measuring points (standard setting)

3

: Use 3 measuring points

Reference angle

Q380 (absolute): Reference angle

(basic rotation) for measuring the measuring points in

the active workpiece coordinate system. Defining a

reference angle can considerably enlarge the

measuring range of an axis. Input range 0 to 360.0000

Calibrate length (0/1)

Q433: Define whether the

TNC is to calibrate the touch probe length after radius

calibration, as well:

0:

Do not calibrate touch probe length

1:

Calibrate touch probe length

Datum for length

Q434 (absolute): Coordinate of the

calibration sphere center. The definition is only

required if length calibration is to be carried out. Input

range -99999.9999 to 99999.9999

Example: NC blocks

5 TCH PROBE 460 CALIBRATE TS

Q407=12.5 ;SPHERE RADIUS

Q320=0

;SET-UP CLEARANCE

Q301=1

;MOVE TO CLEARANCE

Q423=4

;NO. OF PROBE POINTS

Q380=+0

;REFERENCE ANGLE

Q433=0

;CALIBRATE LENGTH

Q434=-2.5 ;DATUM