Notes on the accuracy – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 485

background image

HEIDENHAIN iTNC 530

485

18

.4

MEA

S

URE

KINEMA

TICS

(Cy

cle

451,

DIN/ISO:

G451;

Option)

Notes on the accuracy

The geometrical and positioning error of the machine influences the

measured values and therefore also the optimization of a rotary axis.

For this reason there will always be a certain amount of error.
If there were no geometrical and positioning error, any values

measured by the cycle at any point on the machine at a certain time

would be exactly reproducible. The greater the geometrical and

positioning error, the greater is the dispersion of measured results

when you fix the calibration sphere to different positions in the

machine coordinate system.
The dispersion of results recorded by the TNC in the measuring log is

a measure of the machine's static tilting accuracy. However, the

measuring circle radius and the number and position of measuring

points have to be included in the evaluation of accuracy. One

measuring point alone is not enough to calculate dispersion. For only

one point, the result of the calculation is the spatial error of that

measuring point.
If several rotary axes are moved simultaneously, their error values are

combined. In the worst case they are added together.

If your machine is equipped with a controlled spindle, you

should activate the angle tracking using MP6165. This

generally increases the accuracy of measurements with a

3-D touch probe.
If required, deactivate the lock on the rotary axes for the

duration of the calibration. Otherwise it may falsify the

results of measurement. The machine tool manual

provides further information.