Touch probe cycles: automatic kinematics measurement

18

.5

PRESET

COMPENSA

TION

(Cy

cle

452,

DIN/ISO:

G452,

Option)

Insert the second interchangeable head

Insert the touch probe

Measure the interchangeable head with Cycle 452

Measure only the axes that have actually been changed (in this

example: only the A axis; the C axis is hidden with Q422)

The preset and the position of the calibration sphere must not be

changed during the complete process

All other interchangeable heads can be adjusted in the same way

Example: Adjusting an interchangeable head

3 TOOL CALL "TCH PROBE" Z

4 TCH PROBE 452 PRESET COMPENSATION

Q407=12.5 ;SPHERE RADIUS

Q320=0

;SET-UP CLEARANCE

Q408=0

;RETR. HEIGHT

Q253=2000 ;F PRE-POSITIONING

Q380=45

;REFERENCE ANGLE

Q411=-90

;START ANGLE A AXIS

Q412=+90

;END ANGLE A AXIS

Q413=45

;INCID. ANGLE A AXIS

Q414=4

;MEAS. POINTS A AXIS

Q415=-90

;START ANGLE B AXIS

Q416=+90

;END ANGLE B AXIS

Q417=0

;INCID. ANGLE B AXIS

Q418=2

;MEAS. POINTS B AXIS

Q419=+90

;START ANGLE C AXIS

Q420=+270 ;END ANGLE C AXIS

Q421=0

;INCID. ANGLE C AXIS

Q422=0

;MEAS. POINTS C AXIS

Q423=4

;NO. OF MEAS. POINTS

Q432=0

;BACKLASH, ANG. RANGE

The head change function can vary depending on the

individual machine tool. Refer to your machine manual.