beautypg.com

Please note while programming – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 498

background image

498

Touch probe cycles: automatic kinematics measurement

18

.5

PRESET

COMPENSA

TION

(Cy

cle

452,

DIN/ISO:

G452,

Option)

Please note while programming:

In order to be able to perform a preset compensation, the

kinematics must be specially prepared. The machine tool

manual provides further information.
Note that all functions for tilting in the working plane are

reset. M128 or FUNCTION TCPM are deactivated.
Position the calibration sphere on the machine table so

that there can be no collisions during the measuring

process.
Before defining the cycle you must set the datum in the

center of the calibration sphere and activate it.
For rotary axes without separate position encoders, select

the measuring points in such a way that you have to

traverse a distance of 1° to the limit switch. The TNC

needs this distance for internal backlash compensation.
For the positioning feed rate when moving to the probing

height in the touch probe axis, the TNC uses the value

from cycle parameter Q253 or MP6150, whichever is

smaller. The TNC always moves the rotary axes at

positioning feed rate Q253 while the probe monitoring is

inactive.
If the kinematic data attained in the optimize mode are

greater than the permissible limit (MP6600), the TNC

shows a warning. Then you have to confirm acceptance of

the attained value by pressing NC start.
Note that a change in the kinematics always changes the

preset as well. After an optimization, reset the preset.
In every probing process the TNC first measures the

radius of the calibration sphere. If the measured sphere

radius differs from the entered sphere radius by more than

you have defined in MP6601, the TNC shows an error

message and ends the measurement.
If you interrupt the cycle during the measurement, the

kinematic data might no longer be in the original condition.

Save the active kinematic configuration before an

optimization with Cycle 450, so that in case of a failure the

most recently active kinematic configuration can be

restored.
Programming in inches: The TNC always records the log

data and results of measurement in millimeters.

This manual is related to the following products: