beautypg.com

Positioning direction – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 482

background image

482

Touch probe cycles: automatic kinematics measurement

18

.4

MEA

S

URE

KINEMA

TICS

(Cy

cle

451,

DIN/ISO:

G451;

Option)

Positioning direction

The positioning direction of the rotary axis to be measured is

determined from the start angle and the end angle that you define in

the cycle. A reference measurement is automatically performed at 0°.

The TNC will issue an error message if the selected start angle, end

angle and number of measuring points result in a measuring position

of 0°.
Specify the start and end angles to ensure that the same position is

not measured twice. As mentioned above, a duplicated point

measurement (e.g. measuring positions +90° and -270°) is not

advisable, however it does not cause an error message.

Example: Start angle = +90°, end angle = –90°

Start angle = +90°

End angle = –90°

No. of measuring points = 4

Stepping angle resulting from the calculation = (-90 - +90) / (4-1) =

–60°

Measuring point 1= +90°

Measuring point 2= +30°

Measuring point 3= –30°

Measuring point 4= –90°

Example: start angle = +90°, end angle = +270°

Start angle = +90°

End angle = +270°

No. of measuring points = 4

Stepping angle resulting from the calculation = (270 – 90) / (4 – 1)

= +60°

Measuring point 1= +90°

Measuring point 2= +150°

Measuring point 3= +210°

Measuring point 4= +270°