beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 490

background image

490

Touch probe cycles: automatic kinematics measurement

18

.4

MEA

S

URE

KINEMA

TICS

(Cy

cle

451,

DIN/ISO:

G451;

Option)

Feed rate for pre-positioning

Q253: Traversing

speed of the tool during positioning in mm/min. Input

range 0.0001 to 99999.9999; alternatively FMAX,
FAUTO

, PREDEF

Reference angle

Q380 (absolute): Reference angle

(basic rotation) for measuring the measuring points in

the active workpiece coordinate system. Defining a

reference angle can considerably enlarge the

measuring range of an axis. Input range 0 to 360.0000

Start angle A axis

Q411 (absolute): Starting angle in

the A axis at which the first measurement is to be

made. Input range -359.999 to 359.999

End angle A axis

Q412 (absolute): Ending angle in the

A axis at which the last measurement is to be made.

Input range -359.999 to 359.999

Angle of incid. A axis

Q413: Angle of incidence in

the A axis at which the other rotary axes are to be

measured. Input range -359.999 to 359.999

Number meas. points A axis

Q414: Number of probe

measurements with which the TNC is to measure the

A axis. If the input value = 0, the TNC does not

measure the respective axis. Input range 0 to 12

Start angle B axis

Q415 (absolute): Starting angle in

the B axis at which the first measurement is to be

made. Input range -359.999 to 359.999

End angle B axis

Q416 (absolute): Ending angle in the

B axis at which the last measurement is to be made.

Input range -359.999 to 359.999

Angle of incid. in B axis

Q417: Angle of incidence

in the B axis at which the other rotary axes are to be

measured. Input range -359.999 to 359.999

Number meas. points B axis

Q418: Number of probe

measurements with which the TNC is to measure the

B axis. If the input value = 0, the TNC does not

measure the respective axis. Input range 0 to 12