beautypg.com

Please note while programming, Cycle parameters, Please note while programming: cycle parameters – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 375

background image

HEIDENHAIN iTNC 530

375

15.6 D

A

TUM FR

OM INSIDE OF CIR

C

LE (Cy

cle 412, DIN/ISO:

G412)

Please note while programming:

Cycle parameters

Center in 1st axis

Q321 (absolute): Center of the

pocket in the reference axis of the working plane.

Input range -99999.9999 to 99999.9999

Center in 2nd axis

Q322 (absolute): Center of the

pocket in the minor axis of the working plane. If you

program Q322 = 0, the TNC aligns the hole center to

the positive Y axis. If you program Q322 not equal to

0, then the TNC aligns the hole center to the nominal

position. Input range -99999.9999 to 99999.9999

Nominal diameter

Q262: Approximate diameter of the

circular pocket (or hole). Enter a value that is more

likely to be too small than too large. Input range 0 to

99999.9999

Starting angle

Q325 (absolute): Angle between the

reference axis of the working plane and the first touch

point. Input range -360.0000 to 360.0000

Stepping angle

Q247 (incremental): Angle between

two measuring points. The algebraic sign of the

stepping angle determines the direction of rotation

(negative = clockwise) in which the touch probe

moves to the next measuring point. If you wish to

probe a circular arc instead of a complete circle, then

program the stepping angle to be less than 90°. Input

range -120.0000 to 120.0000

Danger of collision!

To prevent a collision between the touch probe and the

workpiece, enter a low estimate for the nominal diameter

of the pocket (or hole).
If the dimensions of the pocket and the safety clearance

do not permit pre-positioning in the proximity of the touch

points, the TNC always starts probing from the center of

the pocket. In this case the touch probe does not return to

the clearance height between the four measuring points.
The smaller the angle increment Q247, the less accurately

the TNC can calculate the datum. Minimum input value: 5°
Before a cycle definition you must have programmed a

tool call to define the touch probe axis.

X

Y

Q322

Q321

Q262

Q325

Q247