16.7 MEA

S

. RECT

AN. INSIDE (Cy

cle

423, DIN/ISO:

G423)

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:

0

: No measuring log

1

: Generate measuring log: with the standard setting

the TNC saves the log file TCHPR423.TXT in the

directory in which your measuring program is also

stored.

2

: Interrupt the program run and display the

measuring log on the screen. Resume program run

with NC Start.

PGM stop if tolerance error

Q309: Definition of

whether in the event of a violation of tolerance limits

the TNC is to interrupt the program run and output an

error message:

0

: Do not interrupt program run, no error message

1

: Interrupt program run, output an error message

Tool for monitoring

Q330: Definition of whether the

TNC is to monitor the tool (see "Tool monitoring" on

page 414). Input range 0 to 32767.9; alternatively, tool

name with max. 16 characters

0

: Monitoring not active

>0

: Tool number in the tool table TOOL.T

Example: NC blocks

5 TCH PROBE 423 MEAS. RECTAN. INSIDE

Q273=+50

;CENTER IN 1ST AXIS

Q274=+50

;CENTER IN 2ND AXIS

Q282=80

;1ST SIDE LENGTH

Q283=60

;2ND SIDE LENGTH

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+10

;CLEARANCE HEIGHT

Q301=1

;MOVE TO CLEARANCE

Q284=0

;MAX. LIMIT 1ST SIDE

Q285=0

;MIN. LIMIT 1ST SIDE

Q286=0

;MAX. LIMIT 2ND SIDE

Q287=0

;MIN. LIMIT 2ND SIDE

Q279=0

;TOLERANCE 1ST CENTER

Q280=0

;TOLERANCE 2ND CENTER

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL