ND 2100G GAGE-CHEK

267

2.4 F

o

rm

ulas

Setup function

The Setup function is used to specify bar graph parameters for the
current part including:

„

Max value (BarMax)

„

Min value (BarMin)

„

High limit (HiLimit)

„

High warning (HiWarn)

„

Low limit (LoLimit)

„

Low warning (LoWarn)

„

Nominal value (Nominal)

To insert the Setup function:

U

Press the OTHER... soft key

U

Press the XTRA dimension key

U

Use the arrow cursor keys to highlight Setup

U

Press the ENTER key

U

Use the arrow cursor keys to highlight the desired bar graph
parameter

U

Press the ENTER key

Setup function.

Setup function syntax

Hn = SetupParameter(Dimension,value)

Example:

H1 = SetupHiWarn(A,1.75mm)

H1 = SetupHiWarn(B,2.00mm)

H1 = SetupHiWarn(C,2.25mm)

H1 = SetupHiWarn(D,2.50mm)

Sets the Bar graph high warning parameters of dimensions A
through D to different values.