beautypg.com

4 f o rm ulas – HEIDENHAIN ND 2100G User Manual

Page 209

background image

ND 2100G GAGE-CHEK

209

2.4 F

o

rm

ulas

To accomplish this sequence of measurements using only one
channel, the operator performs the following steps from the beginning
of the sequence:

U

Position the block and channel input to measure height (H)

U

Press the ENTER key to store the channel value. The ND 2100G
advances to the next step in the sequence.

H = seq(1,C1)

U

Position the block and channel input to measure width (W)

U

Press the ENTER key to store the new channel value. The
ND 2100G advances to the next step in the sequence.

W = seq(2,C1)