Toa SX-2000 Series Installation User Manual
Matrix system sx-2000 series, Installation manual

INSTALLATION MANUAL
MATRIX SYSTEM
SX-2000 SERIES
When an EN 54-16 compliant SX-2000 system has to be installed, then read "APPENDIX: ADDItIoNAl
INStAllAtIoN INStructIoNS for AN EN 54-16 comPlIANt SyStEm" in this document carefully
and follow up the installation and configuration requirements explained herein. this APPENDIX contains
the basic description of settings and installations, so please refer to the general instruction sections in this
document for more details.
Note
refer to the Instruction manual attached to the VX-2000DS/3000DS for the installation of the the VX-
2000DS or VX-3000DS Emergency power supply, the VX-2000Pf Power supply frame, and the VX-200PS
Power supply unit.
1134
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg, Germany
1134-CPR-102
EN 54-16: 2008
Fire detection and fire alarm systems
— Part 16: Voice alarm control and indicating equipment
Options:
Emergency microphone(s)
Manual reset of the voice alarm condition
Indication of faults related to voice alarm zones
Phased evacuation
Voice alarm condition output to CIE
Redundant power amplifiers
14
DoP 14-003
thank you for purchasing toA's matrix System.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
Document Outline
- 1. NOMENClATURE AND FUNCTIONS
- 1.1. SX-2000SM System Manager
- 1.2. SX-2000AI Audio Input Unit
- 1.3. SX-2100AI Audio Input Unit
- 1.4. SX-2000AO Audio Output Unit
- 1.5. SX-2100AO Audio Output Unit
- 1.6. SX-2000CI Control Input Unit
- 1.7. SX-2000CO Control Output Unit
- 1.8. RM-200SF Fireman's Microphone
- 1.9. RM-200SA Remote Microphone
- 1.10. RM-210 Remote Microphone Extension
- 1.11. RM-200RJ Terminal Unit
- 1.12. Optional Modules
- 1.13. VP-2064, VP-2122, VP-2241, and VP-2421 Power Amplifiers
- 1.14. VP-200VX Power Amplifier Input Module
- 1.15. VP-3154, VP-3304, and VP-3504 Power Amplifiers
- 2. installation
- 2.1. SX-2000SM
- 2.2. SX-2000AI and SX-2100AI
- 2.3. SX-2000AO and SX-2100AO
- 2.3.1. Setting the device number
- 2.3.2. 24 V Emergency cutoff input settings (DIP switch 8 operation) (SX-2000AO only)
- 2.3.3. Converting an output into a transformer-balanced output (SX-2000AO only)
- 2.3.4. Changing the method of power supply for the control input signal applied to the Local Audio Control Input Terminal (SX-2100AO only)
- 2.4. SX-2000CO
- 2.5. RM-200SF, RM-200SA, and RM-210
- 2.5.1. RM-200SF and RM-200SA device number settings (DIP switches 1 – 3 operation)
- 2.5.2. Adjusting microphone sensitivity
- (RM-200SF: DIP switch 5 operation or RM-200SA: DIP switch 4 operation)
- 2.5.3. CPU OFF function (general urgency all-call) settings
- (RM-200SF: DIP switch 6 operation or RM-200SA: DIP switch 5 operation)
- 2.5.4. RM Communication function setting
- (RM-200SF: DIP switch 4 operation or RM-200SA: DIP switch 6 operation)
- 2.5.5. Using an external microphone (RM-200SA only)
- 2.5.6. Compressor function setting
- 2.5.7. Microphone fault detection function setting (RM-200SA only)
- 2.5.8. Installing the RM-200SF on a wall
- 2.5.9. RM-200SA expansion with the addition of the RM-210 (Installed on a flat surface)
- 2.5.10. Installing the RM-200SA on a wall
- 2.5.11. Installing the RM-210 on a wall
- 2.5.12. Creating remote microphone name labels
- 2.6. VP-2064, VP-2122, VP-2241 and VP-2421 Power Amplifiers
- 2.7. VP-3154, VP-3304 and VP-3504 Power Amplifiers
- 2.8. Rack Mounting
- 3. System Configuration Example
- 4. Connections
- 5. SPEAKER LINE INITIAL SETTING
- 6. Inserting a CF Card
- 7. TIME SETTINGS
- 8. KEY LOCK SETTINGS AND CANCELLATION
- 9. OUTPUTTING LOG DATA (SX-2000SM: DIP Switches 1 and 2 operations)
- 10. FAILURE INDICATIONs
- 11. SPECIFICATIONS
- 11.1. SX-2000SM System Manager
- 11.2. SX-2000AI Audio Input Unit
- 11.3. SX-2100AI Audio Input Unit
- 11.4. SX-2000AO Audio Output Unit
- 11.5. SX-2100AO Audio Output Unit
- 11.6. SX-2000CI Control Input Unit
- 11.7. SX-2000CO Control Output Unit
- 11.8. RM-200SF Fireman's Microphone
- 11.9. RM-200SA Remote Microphone
- 11.10. RM-210 Remote Microphone Extension
- 11.11. RM-200RJ Terminal Unit
- 11.12. SX-200RM Remote Microphone Interface Module
- 11.13. D-921E Microphone/Line Input Module
- 11.14. D-921F Microphone/Line Input Module
- 11.15. D-922E Microphone/Line Input Module
- 11.16. D-922F Microphone/Line Input Module
- 11.17. D-936R Stereo Input Module
- 11.18. VP-2064 Power Amplifier 4 x 60 W
- 11.19. VP-2122 Power Amplifier 2 x 120 W
- 11.20. VP-2241 Power Amplifier 1 x 240 W
- 11.21. VP-2421 Power Amplifier 1 x 420 W
- 11.22. VP-3154 Digital Power Amplifier 4 x 150 W
- 11.23. VP-3304 Digital Power Amplifier 4 x 300 W
- 11.24. VP-3504 Digital Power Amplifier 4 x 500 W
- 11.25. VP-200VX Power Amplifier Input Module
- AppendIx: ADDITIONAL INSTALLATION INSTRUCTIONS
- FOR AN EN 54-16 COMPLIANT SYSTEM
- 1. General Information
- 2. Indications and Controls in Access Level1
- 3. Indications and Controls in Access Level 2
- 4. Overview of the Access Level Requirements for the Equipment and related Functions
- 5. Power Supply
- 6. Cabinets
- 7. Standby (reserve, redundant) Amplifiers
- 8. Setting on the System Manager SX-2000SM