• Since the control input terminals use photo couplers, they can be isolated using an external power supply

source. remove the 2 power feed jumpers and 2 isolation jumpers installed on the 6P removable terminal

plug, then make connections as shown below:

+
-

External power supply unit

24 – 40 V DC

TT-104B

OUTPUT CHANNEL (24 V DC 0.5 A)

BE SURE TO SET

THIS SWITCH TO “ON”

AFTER INSTALLATION

ON

MEMORY

BACK UP

CHANNEL

ASSIGNMENT

OFF

ON

OFF

CAUTION

SX-2100AO or SX-2000AO

(The figure below shows the SX-2100AO.)

6P removable terminal plugs

(supplied with the SX-2000AO

and SX-2100AO)

OUTPUT CHANNEL (24 V DC 0.5 A)

Note

Connect an external power supply source

to each right-side terminal of the VCC and

GND terminals.

Control input terminal

Open voltage: Under 40 V DC

Short-circuit current: 2 mA

Cable: AWG22 – 28

twisted pair cable

Cable: AWG22 – 28

twisted pair cable