beautypg.com

Warning – Toa SX-2000 Series Installation User Manual

Page 76

background image

76

2.5.7. Microphone fault detection function setting (RM-200SA only)

the rm-200SA is equipped with the microphone fault detection function, which can be set to off. (factory-

preset to oN)
Notes

• Turn off the power before starting this work.

• To avoid damage from static electricity, never touch the parts on the circuit board.

Step 1. unscrew 8 screws indicated by arrows in the figure at

right, then detach the rm-200SA's upper case.
Note

Note the types of screws.
A: 3 x 8 tapping screw (white silver) ........... 6 pieces

B: 3 x 10 tapping screw (black) ................... 2 pieces

RM-200SA bottom

A

A

B

B

A

A

A

A

SW303

RM-200SA inner circuit board

Front side

SW303

When setting the

microphone fault

detection function

to ON.

(Factory-preset)

When setting the

microphone fault

detection function

to OFF.

SW303

Step 2. Set the jumper's position (SW303) on the circuit board attached to the bottom plate as shown below.

Step 3. replace the rm-200SA's upper case.

Note: Note the types of screws when replacing the upper case (See Step 1.)

this work should only be performed by a qualified professional

electrician. If users open the unit case or modify the unit, this may

cause fire or electric shock.

wARNINg

This manual is related to the following products: