2.2.3. Changing the type of control outputs (SX-2100AI only)

All the contact outputs are of normally open type when shipped from the factory.

Each output can be converted into normally closed type by changing the jumper setting on the cIo circuit

board.

Notes

• Turn off the power before starting this work.

• To avoid damage from static electricity, never touch the terminals themselves or any of the parts on the circuit

board.

Step 1. Detach the SX-2100AI's top panel.

Note

Note the specific shapes of the different screws.
top panel: m3 x 6 flat head machine screw (2 pieces)

Side panel: m3 x 6 binding head machine screw (4 pieces)

Top panel

CIO circuit board

SX-2100AI

this change should only be performed by a qualified professional

electrician. If users open the unit case or modify the unit, this may

cause fire or electric shock.

wARNINg