2.5.4. RM Communication function setting

(RM-200SF: DIp switch 4 operation or RM-200SA: DIp switch 6 operation)

Set the rm communication function to the Automatic Setting (off) or 9600 bps fixed (oN). Normally set to the

Automatic Setting (off). communication may become unstable depending on conditions when cable length

between the unit and remote microphone is great. In such cases, set the switch to 9600 bps fixed (oN). Be

sure to set the DIP switches of all remote microphones in the system to the same position.