Shield
Speaker
End-of-line unit
CH1
CH2
PA LINK
VP-200VX
PA LINK
VP-200VX
28 V
4.8 A
DC POWER IN
PA OUT (SP LINK)
C
H
CH1
C
H
CH2
SX-2100AO
VP-2122
Amplifier output terminal
Amplifier Input Module VP-200VX
Audio signal output
Amplifier intput terminal
PA LINK
VP-200VX
8P removable terminal plug
(supplied with the SX-2100AO)
Applicable cable:
CAT5-STP
Applicable cable:
AWG16 – 24
PA OUT (SP LINK)
C
H
CH1
C
H
CH2
E H C
IMpORTANT
In both Impedance method and Eol method described below, be sure to make the speaker line initial setting
after connection completion when the speaker line surveillance is to be performed.
[Impedance method]
the cable connection in this method is the same as when the surveillance function is not used. (See
to use the surveillance function, make the necessary setting on the SX-2000 Setting Software.
Note
for the setting procedures, refer to the separate Setting Software Instructions.
[EOL method]
Connection between the SX-2100AO and speaker lines