Toa SX-2000 Series Installation User Manual

Page 23

background image

23

37 38

39

40

41 42

42

43

44

45

46

47 48

49

50

51

52

53

SX-2000AO

Note

When the 24 V Emergency cutoff input is set to be

disabled (not usable) with the DIP switch 8 inside

the protective cover, the Emergency indicator

will not flash even if 24 V Dc supply to this input

terminal is cut off.

31. Key Lock Indicator [KEY LOCK]

lights when the output volume controls and

channel keys are locked. (See

p. 152, "Key lock

Settings and cancellation"

)

32. Control Input Unit Connection Indicator [1]

Indicates "1" when the SX-2000cI is connected to

the SX-2000Ao.

33. Control Output Unit Connection Indicator [2]

Indicates "2" when the SX-2000co is connected

to the SX-2000Ao.

34. Monitor Level Meter

Indicates the sound volume level of the output

channel being monitored.

35. Monitor Level Meter Scale

lights when the monitor oN/off key (15) is set

to oN.

36. Monitor ON/OFF Indicator [LEvEL]

lights when the monitor oN/off key (15) is set

to oN.

37. Functional Earth Terminal [SIgNAL gND]

Hum noise may be generated when external

equipment is connected to the unit. connecting

this terminal to the functional earth terminal of the

external equipment may reduce the hum noise.

Note: this terminal is not for protective earth.

38. DC power Input Terminal [DC pOwER IN]

connect an optional Dc power supply unit to

this terminal. Select the Dc power supply source

with consideration given to the current power

consumption of the system the SX-2000Ao is to

be connected to. When not using a redundant

power system*, connect the [+] terminal of input A

to the [+] terminal of input B, and the [–] terminal

of input A to the [–] terminal of input B.

(refer to the Instruction manual attached to the

VX-2000DS/3000DS.)
*

A method of connecting separate power

sources to each power input or connecting the

commercial power supply and backup power

supply separately to each power input to prevent

the system from going down when a cable is

broken or power fails.

39. Control Output Terminals

[CONTROL OUTpUT 1 – 8]

relay make contact outputs.

Each contact capacity is rated at 40 V Dc for

withstand voltage, and 2 mA – 300 mA for control

current.

these terminals are controlled by the SX-2000

Setting Software. (See the separate Setting

Software Instructions, "Pattern Settings.")

40. power Feed Jumper 2 [vCC]

the supplied removable terminal plug is equipped

with a jumper.

When the jumper is attached, the circuits of

control inputs 3, 4, 7, and 8 are powered from

inside the SX-2000Ao.

removing the jumper disconnects this internal

power supply and thus requires that power be

supplied externally to the circuit. (See

"operation

of Power feed Jumper and Isolation Jumper" on

the next page

.)

[Rear]