11.7. SX-2000CO Control Output Unit

Power Source

24 V Dc (operational range: 20 V – 40 V Dc),

2 channels of power inputs for accepting redundant power supply

current consumption

under 0.34 A (maximum value in the power operating range)

under 0.29 A (at 24 V Dc operation)

Indication

control output indicators, Power indicator, cPu-off indicator, fault indicator

control output

32 outputs, no-voltage make contacts, relay contact outputs

(withstand voltage: 40 V Dc, control current: 2 – 300 mA),

removable terminal blocks (6P x 16)

cI/co link

Input/output

Input: 1 channel, rJ45 connector

output: 1 channel, rJ45 connector

connection cable

Shielded category 5 twisted pair cable for lAN (cAt5-StP)

(each one pair of data wire and control wire)

maximum cable Distance

800 m

operating temperature

0°c to 40°c

operating Humidity

35% to 80% rH (no condensation)

finish

Panel: Aluminum, black, alumite

case: Surface-treated steel plate

Dimensions

482 (w) x 44 (h) x 331.5 (d) mm

Weight

3.6 kg

• Accessories

removable terminal plug (6 pins) ........................................... 16

removable terminal plug (4 pins) ............................................. 1

rack mounting screw with plain washer (5 x 12) ..................... 4

Note: the design and specifications are subject to change without notice for improvement.