Sx-2000co control output unit, Sx-2000co, Control output – Toa SX-2000 Series Installation User Manual
Page 169: Unit

169
11.7. SX-2000CO Control Output Unit
Power Source
24 V Dc (operational range: 20 V – 40 V Dc),
2 channels of power inputs for accepting redundant power supply
current consumption
under 0.34 A (maximum value in the power operating range)
under 0.29 A (at 24 V Dc operation)
Indication
control output indicators, Power indicator, cPu-off indicator, fault indicator
control output
32 outputs, no-voltage make contacts, relay contact outputs
(withstand voltage: 40 V Dc, control current: 2 – 300 mA),
removable terminal blocks (6P x 16)
cI/co link
Input/output
Input: 1 channel, rJ45 connector
output: 1 channel, rJ45 connector
connection cable
Shielded category 5 twisted pair cable for lAN (cAt5-StP)
(each one pair of data wire and control wire)
maximum cable Distance
800 m
operating temperature
0°c to 40°c
operating Humidity
35% to 80% rH (no condensation)
finish
Panel: Aluminum, black, alumite
case: Surface-treated steel plate
Dimensions
482 (w) x 44 (h) x 331.5 (d) mm
Weight
3.6 kg
• Accessories
removable terminal plug (6 pins) ........................................... 16
removable terminal plug (4 pins) ............................................. 1
rack mounting screw with plain washer (5 x 12) ..................... 4
Note: the design and specifications are subject to change without notice for improvement.