[when power is supplied from the SX-200RM]

• The following table shows the maximum cable distance when STP Category 5 straight cable (with RJ45

connectors) is used.

No. of expansion

units RM-200SA alone

RM-200SA +

RM-210 x 1

RM-200SA +

RM-210 x 2

RM-200SA +

RM-210 x 3

RM-200SA +

RM-210 x 4

Cable

STP Category 5

140 m

120 m

100 m

90 m

80 m

• To make longer cable lengths than those shown in the above table, use over 4-pair shielded CPEV cable. (For

the cable connection, see below.)

the relationship of the cPEV cable conductor diameter to the maximum cable distance is as follows:

No. of expansion

units

RM-200SA

alone

RM-200SA +

RM-210 x 1

RM-200SA +

RM-210 x 2

RM-200SA +

RM-210 x 3

RM-200SA +

RM-210 x 4

Conductor diameter

ø0.65 mm

230 m

190 m

170 m

150 m

130 m

ø0.9 mm

460 m

380 m

330 m

290 m

260 m

ø1.2 mm

800 m

670 m

570 m

500 m

450 m

RM-200SA rear

Connection cable

(with RJ45 connectors)

To SX-200RM

Connecting the SX-200RM to the RM-200SA