2.3.2. 24 v Emergency cutoff input settings (DIp switch 8 operation) (SX-2000AO only)

the 24 V Emergency cutoff input can be set to be enabled or disabled.

once enabled when the SX-2000 system is combined with an emergency broadcast system, a 24 V Dc is

normally kept being supplied to this 24 V emergency cutoff input terminal and is cut off (24 V emergency cutoff

function) in emergency situations. this interrupts the general-purpose broadcast from the SX-2000, allowing

the emergency broadcast to override it. At the same time, the EmErGENcy indicators flash, one on the

SX-2000Sm's front panel and others in the fluorescent displays on the front panels of SX-2000Aos in 24 V

emergency cutoff state.

Note

When using this input terminal in combination with an emergency broadcast system, set DIP switch 8 to oN.

Step 1. remove the protective cover on the SX-2000Ao's front panel by unscrewing it with a Phillips screwdriver.

01234

5678

9AB

CD

EF

01234

5678

9AB

CD

EF

Protective cover

Screw

DIP switch

Reset key

Inside of the protective cover

Step 2. Set the DIP switch.
2-1. If using the 24 V emergency cutoff input, set DIP switch 8 to oN.

2-2. If not using the 24 V emergency cutoff input, set DIP switch 8 to off.

Step 3. replace the protective cover.

Note: Switch 8 is set to off

by default.

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8