[Rear]

21

16

18 19

17

20

16. power Input Terminal [DC pOwER IN]

connect an optional AD-246 Ac adapter to this

terminal when extending cable length. Power

is usually supplied to the rm-200SA and rm-

210 from the SX-200rm remote microphone

Interface module. (See

p. 109

.)

17. USB Terminal [USB]

Not used.

18. RM Link Terminal [RM LINK]

used to connect an SX-200rm remote

microphone Interface module via a StP category

5 cable.

19. Speaker volume Control [Sp]

Adjusts the volume of the built-in speaker.

20. Microphone volume Control [MIC]

Adjusts the volume of the microphone (1) and the

external microphone connected via the external

microphone input terminal (21).

21. External Microphone Input Terminal

[EXTERNAL MIC IN]

connect an optional external microphone*

1

to this

terminal.

Jumper settings on the circuit board must be

changed depending on the input sources. (See

p. 72

.)

Specifications: –40 dB*

2

, 2.2 kΩ, unbalanced,

mini-jack, and phantom power.

*

1

the WH-4000A, yP-m101, or yP-m301 can be

used for the external microphone.

*

2

0 dB = 1 V