[when each individual channel is displayed on the fluorescent display after the initial value

has been set]
• The 5th indicator (segment) from the bottom of the selected channel's level meter lights up after

completion of the initial value setting. this value is the reference value.

• The level indicator goes up and down in response to the current value. The meter shows a short state

of speaker line in the range above the reference value, and an open state in the range below it.

• Current impedance status of the selected channel can be checked in the text display area.

current value: Displays the ratio of current impedance to the initial one in real-time.

this indicator remains unlit when the speaker line is not connected. the display

range is 0 to 9999 and over. A blank is displayed if no initial setting is or could

have been performed.

Judgment:

Displays the judgment results below.

SHORT

NORMAL

OPEN

EARTH

– – –

Judgment

Line shorted

Line normal

Line open

Ground fault

Initial value is not set.