beautypg.com

Via rm-200rj as needed) – Toa SX-2000 Series Installation User Manual

Page 105

background image

105

4.2.2. Connecting the SX-200RM to the RM-200SF or RM-200SA (via RM-200RJ as needed)

connect the rm link terminal of the SX-200rm unit mounted in the SX-2000AI or SX-2100AI to the terminal

block of the rm-200Sf or the rm lINK terminal of the rm-200SA. the length of the connection cable differs

depending on the method of power supply and the type of cable used.

Note

connect the rm-200Sf or rm-200SA individually to each input of the SX-200rm mounted in the SX-2000AI

or SX-2100AI.

the input channel to which the rm-200Sf or rm-200SA can be connected is assigned by the SX-2000 Setting

Software and indicated by the orange rm1 or rm2 status indicator. connect the rm-200Sf or rm-200SA

assigned the same device number as the SX-2000AI's or SX-2100AI's input channel number to the rm lINK

terminal.

(for the rm-200Sf and rm-200SA device number settings, see

p. 66

.)

FOR SX-2000 SERIES ONLY

RM-200SF

RM-200SA

Connection cable

(with RJ45 connectors)

RM LINK

RM2 status LED

RM1 status LED

SX-200RM

FIREMAN'S MICROPHONE

RM-200SF

REMOTE MICROPHONE

RM-200SA

Terminal block