4. CONNECTIONS

4.1. Removable Terminal plug Connection

Notes
• Use the screwdriver supplied with the SX-2000SM when connecting the removable terminal connector.
• Do not use a micro screwdriver. Sufficient torque is not given to the screws when tightening them, and

connections may not be secured.

• Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened

and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.

• When connecting 2 cables or a shielded cable to a single terminal,

use a ferrule terminal with an insulation sleeve to crimp the cables

because such cable conductors could become loose.

recommended ferrule terminals for signal cables

(made by Phoenix contact)

recommended ferrule terminals for power supply cables

(made by Phoenix contact)

crimping tool: crImPfoX uD6-4 (made by Phoenix contact)

wiring procedures
Procedures below are for the removable terminal plug with fixing screws.

Step 1. Wiring the supplied removable terminal plug.
1-1. loosen the terminal screws to insert the wire.
1-2. tighten the terminal screws.

Ensure that the wire does not break free when

pulled.
If the wire does pull free, repeat the connection

procedure from the start.

Step 2. Insert the wired terminal plug into the

corresponding terminal block in the unit's rear

panel.

Step 3. Tighten the fixing screw.
Notes

• Do not reverse Steps 1 and 2 above. Force is applied to the connected receptacle pins while tightening the

terminal screw and they may be damaged, resulting in bad connector contact.

• When detaching the terminal plug, pull it straight out. Pulling it out at an angle may cause the terminal plug or

terminal block to break.

Solid cable and stranded cable

Shielded cable

7 mm*

7 mm*

15 mm

To tighten

To loosen

Removable terminal plug

Terminal screw

Fixing screw

Screwdriver

(supplied with the SX-2000SM)

Cable sheath to trim

Insulation sleeve

Contact section

Insulation sleeve

Contact section

a

l

2

a

1

a

2

l

1

l

2

l

1

b

b

Model Number

a

l

1

l

2

AI 0,34-8 TQ
AI 0,5-8 WH

2 mm

2.5 mm

12.5 mm

14 mm

8 mm
8 mm

b

0.8 mm
1.1 mm

Model Number

a

1

l

1

l

2

AI 1,5-8 BK
AI-TWIN 2 x 1,5-8 BK

6.6 mm

a

2

3.6 mm

14 mm
16 mm

2.3 mm

8 mm
8 mm

a

3.4 mm

b

1.8 mm

* Expose 8 mm or more when using the

above ferrule terminal, and cut off an extra

conductor protruding from the sleeve.