Ptp currentds, Ptp parentds, Ptp timingproperties – Interlogix NS3550-8T-2S User Manual User Manual
Page 473: Ptp portdataset

User’s Manual of NS3550-8T-2S
473
PTP CurrentDS
Description:
Show PTP clock Current Data set.
Syntax:
PTP CurrentDS
Parameters:
: clock instance number [0..3]
PTP ParentDS
Description:
Show PTP clock Parent Data set.
Syntax:
PTP ParentDS
Parameters:
: clock instance number [0..3]
PTP Timingproperties
Description:
Set or show PTP clock Timing properties Data set.
Syntax:
PTP Timingproperties
[
Parameters:
: clock instance number [0..3]
: PTP clock offset between UTC and TAI in seconds
: The offsetvalid parameter takes the following values:
false
: The UTC offset is not valid
true
: The UTC offset is valid
: The leap59 parameter takes the following values:
false
: no leap59 in current day
true
: last minute of current day contains 59 sec.
: The leap61 parameter takes the following values:
false
: no leap61 in current day
true
: last minute of current day contains 61 sec.
: The timetraceable parameter takes the following values:
false
: timing is not traceable
true
: timing is traceable.
: The freqtraceable parameter takes the following values:
False
: frequency is not traceable
true
: frequency is traceable.
: The timescale parameter takes the following values:
false
: timing is not a PTP time scale
true
: timing is a PTP time scale.
: [0..255] Time source.
16 (0x10) ATOMIC_CLOCK
32 (0x20) GPS
48 (0x30) TERRESTRIAL_RADIO
64 (0x40) PTP
80 (0x50) NTP
96 (0x60) HAND_SET
144 (0x90) OTHER
160 (0xA0) INTERNAL_OSCILLATOR
PTP PortDataSet
Description:
Set or show PTP port data set.