beautypg.com

2 ptp status – Interlogix NS3550-8T-2S User Manual User Manual

Page 291

background image

User’s Manual of NS3550-8T-2S

291

4.18.2 PTP Status

This section allows the user to inspect the current Precision Time Protocol (PTP) clock settings.

Figure 4-18-3:

PTP Clock Status page screenshot

The page includes the following fields:

Object

Description

One_pps_mode

Shows the current One_pps_mode configured.

1. Output : Enable the 1 pps clock output
2. Input : Enable the 1 pps clock input
3. Disable : Disable the 1 pps clock in/out-put

External Enable

Shows the current External clock output configuration.

1. True : Enable the external clock output
2. False : Disable the external clock output

VCXO_Enable

Shows the current VCXO rate adjustment configuration.

1. True : Enable the external VCXO rate adjustment
2. False : Disable the external VCXO rate adjustment

Clock Frequency

Shows the current clock frequency used by the External Clock.
The possible range of values are 1 - 25000000 (1 - 25MHz)

Clock Instance

Indicates the Instance of a particular Clock Instance [0..3].
Click on the Clock Instance number to monitor the Clock details

Device Type

Indicates the Type of the Clock Instance. There are five Device Types.

1. Ord-Bound - Clock's Device Type is Ordinary-Boundary Clock.
2. P2p Transp - Clock's Device Type is Peer to Peer Transparent Clock.
3. E2e Transp - Clock's Device Type is End to End Transparent Clock.
4. Master Only - Clock's Device Type is Master Only.
5. Slave Only - Clock's Device Type is Slave Only.

Port List

Shows the ports configured for that Clock Instance.



Buttons

Auto-refresh

: Check this box to refresh the page automatically. Automatic refresh occurs every 6 seconds.

: Click to refresh the page immediately.