2 rmon alarm details – Interlogix NS3550-8T-2S User Manual User Manual
Page 277
User’s Manual of NS3550-8T-2S
277
OutQLen
: The length of the output packet queue (in packets).
53. Sample
Type
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute
: Get the sample directly.
Delta
: Calculate the difference between samples (default).
54. Value
The value of the statistic during the last sampling period.
55. Startup
Alarm
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Rising
Trigger alarm when the first value is larger than the rising threshold.
Falling
Trigger alarm when the first value is less than the falling threshold.
RisingOrFalling
Trigger alarm when the first value is larger than the rising
threshold or less than the falling threshold (default).
Rising Threshold
Rising threshold value (-2147483648-2147483647).
Rising Index
Rising event index (1-65535).
Falling Threshold
Falling threshold value (-2147483648-2147483647)
Falling Index
Falling event index (1-65535).
Buttons
: Click to add a new community entry.
: Click to save changes.
:
Click to undo any changes made locally and revert to previously saved values.
4.17.2 RMON Alarm Details
This page provides details of a specific RMON statistics entry; screen in
Figure 4-17-2
appears.
Figure 4-17-2:
Detailed RMON Alarm ID page screenshot
The page includes the following fields:
Object
Description
Interval
Indicates the interval in seconds for sampling and comparing the rising and
falling threshold.
Variable
Indicates the particular variable to be sampled
Sample Type
The method of sampling the selected variable and calculating the value to be
compared against the thresholds.