Hold Off Time
The timing value to be used to make persistent check on Signal Fail before
switching.
The range of the hold off timer is 0 to 10 seconds in steps of 100 ms
Version
ERPS Protocol Version - v1 or v2
Revertive
In Revertive mode, after the conditions causing a protection switch has cleared,
the traffic channel is restored to the working transport entity, i.e., blocked on the
RPL.
In Non-Revertive mode, the traffic channel continues to use the RPL, if it is not
failed, after a protection switch condition has cleared.
VLAN Config
VLAN configuration of the Protection Group. Click on the "VLAN Config" link to
confure VLANs for this protection group.
PRL Configuration:
Object
Description
PRL Role
It can be either RPL owner or RPL Neighbour.
PRL Port
This allows to select the east port or west port as the RPL block.
Clear
If the owner has to be changed, then the clear check box allows to clear the RPL
owner for that ERPS ring.
Instance Command:
Object
Description
Command
Administrative command. A port can be administratively configured to be in either
manual switch or forced switch state.
Port
Port selection - Port0 or Port1 of the protection Group on which the command is
applied.
Instance State:
Object
Description
Protection State
ERPS state according to State Transition Tables in G.8032.
Port 0
OK
: State of East port is ok
SF
: State of East port is Signal Fail
Port 1
OK
: State of West port is ok
SF
: State of West port is Signal Fail
Transmit APS
The transmitted APS according to State Transition Tables in G.8032.
Port 0 Receive APS
The received APS on Port 0 according to State Transition Tables in G.8032.
Port 1 Receive APS
The received APS on Port 1 according to State Transition Tables in G.8032.
WTR Remaining
Remaining WTR timeout in milliseconds.
RPL Un-blocked
APS is received on the working flow.
No APS Received
RAPS PDU is not received from the other end.
Port 0 Block Status
Block status for Port 0 (Both traffic and R-APS block status). R-APS channel is
never blocked on sub-rings without virtual channel.
Port 1 Block Status
Block status for Port 1 (Both traffic and R-APS block status). R-APS channel is
never blocked on sub-rings without virtual channel.
FOP Alarm
Failure of Protocol Defect(FOP) status. If FOP is detected, red LED glows; else
green LED glows.