Erps rpl owner, Erps rpl neighbour clear, Erps rpl owner clear – Interlogix NS3550-8T-2S User Manual User Manual
Page 469: Erps hold off timeout
User’s Manual of NS3550-8T-2S
469
Parameters:
: RPL Block
: protection group id 1 - 64
ERPS RPL Owner
Description:
Selection of RPL Block for a protection group
by default this node is considered as RPL Owner
(east|west) : select east(Port 0) or west(Port 1) as RPL Block
Syntax:
Erps rpl owner
Parameters:
: RPL Block
: protection group id 1 - 64
ERPS RPL Neighbour Clear
Description:
make this node as non-neighbour for a protection group
Syntax:
Erps rpl neighbour clear
Parameters:
: protection group id 1 - 64
ERPS RPL Owner Clear
Description:
making a node as Non-RPL Block for a protection group
After clear, this node is nore an rpl owner for the given group
(east|west) : selected east(Port 0) or west(Port 1) as RPL Block
Syntax:
Erps rpl owner clear
Parameters:
: protection group id 1 - 64
ERPS Hold Off Timeout
Description:
configuring hold off timeout for a protection group
in milliseconds 0-10000 in the increments of 100ms
Syntax:
Erps hold off timeout
Parameters:
: timer timeout values
: protection group id 1 - 64