4.17.7 RMON History Configuration

Configure RMON History table on this page. The entry index key is ID; screen in

Figure 4-17-7

appears.

Figure 4-17-7:

RMON history configuration page screenshot


The page includes the following fields:

Object

Description

Delete

Check to delete the entry. It will be deleted during the next save.

ID

Indicates the index of the entry. The range is from 1 to 65535.

Data Source

Indicates the port ID which wants to be monitored. If in stacking switch, the value
must add 1000*(switch ID-1), for example, if the port is switch 3 port 5, the value
is 2005.

Interval

Indicates the interval in seconds for sampling the history statistics data. The
range is from 1 to 3600, default value is 1800 seconds.

Buckets

Indicates the maximum data entries associated this History control entry stored in
RMON. The range is from 1 to 3600, default value is 50.

Buckets Granted

The number of data will be saved in the RMON.


Buttons

: Click to add a new community entry.

: Click to save changes.

:

Click to undo any changes made locally and revert to previously saved values.