Interlogix NS3550-8T-2S User Manual User Manual
Page 222
User’s Manual of NS3550-8T-2S
222
IP Address
-
IP address and UDP port for the accounting
server in question.
State
-
Shows the state of the server. It takes one of
the following values:
Disabled
: The selected server is disabled.
Not Ready
: The server is enabled, but IP
communication is not yet up and running.
Ready
: The server is enabled, IP
communication is up and running, and the
RADIUS module is ready to accept accounting
attempts.
Dead (X seconds left)
: Accounting attempts
were made to this server, but it did not reply
within the configured timeout. The server has
temporarily been disabled, but will get
re-enabled when the dead-time expires. The
number of seconds left before this occurs is
displayed in parentheses. This state is only
reachable when more than one server is
enabled.
Round-Trip
Time
radiusAccClientExtRo
undTripTime
The time interval (measured in milliseconds)
between the most recent Response and the
Request that matched it from the RADIUS
accounting server. The granularity of this
measurement is 100 ms. A value of 0 ms
indicates that there hasn't been round-trip
communication with the server yet.
Buttons
Auto-refresh
: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds.
: Click to refresh the page immediately.
: Clears the counters for the selected server. The "Pending Requests" counter will not be cleared by this operation.