beautypg.com

0x609a, 0x607c, Object (homing acceleration) – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 78: Object (homing speeds)

background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

78

L

EDS94TA11010xxxx EN 1.2 - 03/2010

0x609A - Homing acceleration

3.9.3

Behaviour of the home position after mains switching

If the reference position/information is to remain available after mains switching, the

setting C02652 = "1: Received" must be selected. Furthermore, the max. permissible angle

of rotation of the encoder, which can be adjusted in C02653, must be observed.

Index | Name:

0x609A | Homing acceleration

Data type: UNSIGNED_32

Code:

C03615

For the reference search two accelerations (and decelerations) can be parameterised to reduce homing time and

increase accuracy:

Subindex Name

0x609A/1

Acc. during search for switch

0x609A/2

Acc. during search for zero

Index | Name:

0x609A/1 | Acc. during search for switch

Data type: UNSIGNED_32

Code: C02645

Acceleration 1 (and deceleration 1) which causes a quick approach of the limit switch/reference switch (depending

on the mode selected).

• Direct mapping of the Lenze code C02645 (homing: acceleration 1).
Setting range

(min. value | unit | max. value)

Lenze setting

0

acc unit

2147483647 0 acc unit

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x609A/2 | Acc. during search for zero

Data type: UNSIGNED_32

Code: C02647

Acceleration 2 (and deceleration 2) which causes the touch probe sensor to be approached slower (but more

precisely) after reversing on the limit switch/enabling the reference switch and the subsequent positioning to the

target position.

• Direct mapping of the Lenze code C02647 (homing: acceleration 2).
Setting range

(min. value | unit | max. value)

Lenze setting

0

acc unit

2147483647 0 acc unit

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Note!

When resolvers or single-turn absolute value encoders are used and the mains is

switched off (24 V supply off), the encoder may only be moved by ½ revolution

since otherwise the home position will get lost due to the ambiguity of the

encoder information.