beautypg.com

Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 107

background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

107

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

CiA402 Homing method 23

Processes:

Case 1:

Axis does not activate reference switch on the way to the limit switch:

1. Movement in positive direction with profile data set 1.
2. Reversing to positive travel range limit switch.
3. Positive edge of the reference switch activates profile data set 2.
4. The following negative edge of reference switch sets reference (

0x607C

).

5. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

Case 2:

Axis activates reference switch first on the way to the limit switch:

1. Movement in positive direction with profile data set 1.
2. Reversing with positive edge of the reference switch and change to profile data set 2.
3. The following negative edge of reference switch sets reference (

0x607C

).

4. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

Case 3:

Axis already stands on reference switch:

1. Movement in negative direction with profile data set 2.
2. The following negative edge of reference switch sets reference (

0x607C

).

3. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

 Homing switch

 Positive travel range limit switch

1

3

2

0

1