3 attribute table, Attribute table, Parameter reference attribute table – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 220
9400 Technology applications | CiA402 device profile
Parameter reference
Attribute table
220
L
EDS94TA11010xxxx EN 1.2 - 03/2010
5.3
Attribute table
The Attribute table contains information required for communicating with the controller
via parameters.
How to read the table of attributes:
Attribute table
Column
Meaning
Entry
Code
Parameter designation
Cxxxxx
Name
Short parameter text (display text)
Text
Index
dec
Index under which the parameter is addressed.
The subindex of array variables corresponds to the
Lenze subcode number.
24575 - Lenze code number
Only required for access via bus
system.
hex
5FFF
h
- Lenze code number
Data
DS
Data structure
E
Single variable
(only one parameter element)
A
Array variable
(several parameter elements)
DA
Number of array elements (subcodes)
Number
DT
Data type
BITFIELD_8
1 byte bit-coded
BITFIELD_16
2 bytes bit-coded
BITFIELD_32
4 bytes bit-coded
INTEGER_8
1 byte with sign
INTEGER_16
2 bytes with sign
INTEGER_32
4 bytes with sign
UNSIGNED_8
1 byte without sign
UNSIGNED_16
2 bytes without sign
UNSIGNED_32
4 bytes without sign
VISIBLE_STRING
ASCII string
Factor
Factor for data transmission via bus system,
depending on the number of decimal positions
Factor
1 ≡ no decimal positions
10 ≡ 1 decimal position
100 ≡ 2 decimal positions
1000 ≡ 3 decimal positions
Access
R
Read access
;
Reading allowed
W
Write access
;
Writing allowed
CINH
Controller inhibit required
;
Writing only possible when controller is inhibited
Code
Name
Index
Data
Access
dec
hex
DS
DA
DT
Factor
R
W
CINH
UG min threshold
21574
5446
E
1
INTEGER_32
100
;
;
Selection of limiter / safety
interconnection
21573
5445
E
1
UNSIGNED_8
1
;
;
Max. telegram failure value
21565
543D
E
1
UNSIGNED_32
1
;
;
Counter SingleError
21564
543C
E
1
INTEGER_32
1
;
Counter MultiError
21563
543B
E
1
INTEGER_32
1
;
Reset Errorcounter
21562
543A
E
1
UNSIGNED_8
1
;
;
CiA402 profile
21075
5253
E
1
UNSIGNED_32
1
;
Motor type
21072
5250
E
1
UNSIGNED_16
1
;
;
Motor catalogue number
21071
524F
E
1
VISIBLE_STRING
1
;
;
Motor manufacturer
21070
524E
E
1
VISIBLE_STRING
1
;
;
http motor catalogue address
21069
524D
E
1
VISIBLE_STRING
1
;
;
Motor calibration date
21068
524C
E
1
VISIBLE_STRING
1
;
;
Motor service period
21067
524B
E
1
UNSIGNED_32
1
;
;
Motor data
21066
524A
E
1
UNSIGNED_32
1
;