4 parameter attributes, Parameter attributes, Abbreviations used in parameter & selection texts – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 197: The table footer contains the

EDS94TA11010xxxx EN 1.2 - 03/2010
L
197
9400 Technology applications | CiA402 device profile
Parameter reference
Structure of the parameter descriptions
5.1.4
Parameter attributes
Description structure
Parameter attributes are listed in the table footer:
Meaning of the attributes
Scaling factor
The "scaling factor" is important for the parameter access via a bus system:
5.1.5
Abbreviations used in parameter & selection texts
Since the character length of the parameter and selection texts is limited, the following
abbreviations are used:
;
Read access ; Write access CINH PLC STOP No transfer
Attribute
Meaning
;
Read access
Read access to parameter possible.
;
Write access
Write access to parameter possible.
• Please also observe the following attributes:
;
CINH
Parameter value can only be changed when the
controller is inhibited.
;
PLC STOP
Parameter value can only be changed when the
application is stopped.
;
No transfer
When you carry out the command download parameter set the parameter is not
transfered to the regenerative power supply module.
Read value (via bus system)
Scaling factor Indicated value (Engineer)
⋅
=
Abbreviation
Meaning
CAN module
CANopen communication module (E94AYCCA)
ENP
Electronic nameplate
MXI1
Module eXtension Interface 1 - module slot for extension 1
MXI2
Module eXtension Interface 2 - module slot for extension 2