C03514 | supported drive modes, C03515 | digital inputs, C03516 | digital outputs – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 201: C03517 | physical outputs, C03518 | bit mask, C03519 | abort connection option code, Code, C03519, C03516, C03517

EDS94TA11010xxxx EN 1.2 - 03/2010
L
201
9400 Technology applications | CiA402 device profile
Parameter reference
Parameter list | C03514
C03514
C03515
C03516
C03517
C03518
C03519
Parameter | Name:
C03514 | Supported drive modes
Data type: UNSIGNED_32
Index: 21061
d
= 5245
h
CiA402 object
Display range
(min. value | unit | max. value)
0
4294967295
;
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C03515 | Digital inputs
Data type: UNSIGNED_8
Index: 21060
d
= 5244
h
CiA402 object
Display range
(min. value | unit | max. value)
0
255
;
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C03516 | Digital outputs
Data type: UNSIGNED_8
Index: 21059
d
= 5243
h
CiA402 object
Display range
(min. value | unit | max. value)
2
2
;
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C03517 | Physical outputs
Data type: UNSIGNED_8
Index: 21058
d
= 5242
h
CiA402 object
Display range
(min. value | unit | max. value)
0
255
;
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C03518 | Bit mask
Data type: UNSIGNED_8
Index: 21057
d
= 5241
h
CiA402 object
Setting range
(min. value | unit | max. value)
Lenze setting
255
255 255
;
Read access ; Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C03519 | Abort connection option code
Data type: INTEGER_16
Index: 21056
d
= 5240
h
CiA402 object
Setting range
(min. value | unit | max. value)
Lenze setting
3
3 3
;
Read access ; Write access CINH PLC STOP No transfer
Scaling factor: 1