beautypg.com

0x605a, 0x605b, 0x605c – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 44: 0x605d, 0x605e, Parameter setting & configuration device control

background image

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Device control

44

L

EDS94TA11010xxxx EN 1.2 - 03/2010

0x605A - Quick stop option code

0x605B - Shutdown option code

0x605C - Disable operation option code

0x605D - Halt option code

0x605E - Fault reaction option code

Index | Name:

0x605A | Quick stop option code

Data type: INTEGER_16

Code:

C03534

Response to request for quick stop.

2 = activate quick stop.

quick stop

Setting range

(min. value | unit | max. value)

Lenze setting

2

2 2

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x605B | Shutdown option code

Data type: INTEGER_16

Code:

C03532

Response to request for drive shutdown.

0 = set controller inhibit.
Setting range

(min. value | unit | max. value)

Lenze setting

0

0 0

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x605C | Disable operation option code

Data type: INTEGER_16

Code:

C03533

Response to deselection of the operating mode.

0 = set controller inhibit.
Setting range

(min. value | unit | max. value)

Lenze setting

0

0 0

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x605D | Halt option code

Data type: INTEGER_16

Code:

C03535

Response to halt command.

2 = activate quick stop.

quick stop

Setting range

(min. value | unit | max. value)

Lenze setting

2

2 2

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x605E | Fault reaction option code

Data type: INTEGER_16

Code:

C03536

Response to drive fault.

2 = activate quick stop.

quick stop

Setting range

(min. value | unit | max. value)

Lenze setting

2

2 2

;

Read access ; Write access … CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX