3 countmultierror, 4 countsingleerror, 5 detecterrorlimit – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 183: Countmultierror, Countsingleerror, Detecterrorlimit
EDS94TA11010xxxx EN 1.2 - 03/2010
L
183
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Parameterisable function blocks
3.21.3
CountMultiError
3.21.4
CountSingleError
3.21.5
DetectErrorLimit
is ans instance of
Function
L_TbCount
Counter for recognised telegram failures (multiple errors)
Parameter
Possible settings
Information
C04006
Reset function
0 After reaching the reference value
the counter is automatically reset to
the starting value.
1 The reference value reached is
stored until it is reset via
bLoadStartValue.
Lenze setting
is ans instance of
Function
L_TbCount
Counter for recognised telegram failures (single errors)
Parameter
Possible settings
Information
C04005
Reset function
0 After reaching the reference value
the counter is automatically reset to
the starting value.
1 The reference value reached is
stored until it is reset via
bLoadStartValue.
Lenze setting
is ans instance of
Function
L_TbCompare
Error triggering after exceeding the maximum value of the telegram failure
• Comparison of the number of recognised telegram failures with the maximum
value set in
.
Parameter
Possible settings
Information
C04085
Comparison operation
0 dnIn1 = dnIn2
1 dnIn1 > dnIn2
Lenze setting
2 dnIn1 < dnIn2
3 |dnIn1| = |dnIn2|
4 |dnIn1| > |dnIn2|
5 |dnIn1| < |dnIn2|