beautypg.com

4 settings for "homing mode, 5 settings for "interpolated position mode, 6 speed feedforward control – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 189: Settings for "homing mode, Settings for "interpolated position mode, Speed feedforward control

background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

189

9400 Technology applications | CiA402 device profile

Step-by-step commissioning

Settings for "Homing mode"

4.4

Settings for "Homing mode"

For "Homing mode" the following parameters must be set:

4.5

Settings for "Interpolated position mode"

For the "Interpolated position mode" the following parameters must be set:

[4-2]

Definition of the interpolation cycle time

4.6

Speed feedforward control

The source for the speed feedforward control can be selected in C02680 (CiA402 object

0x5587).

 The following options are available:

– The source for feedforward control is the

0x60FF

object (target velocity).

– The value for the feedforward control is derived from the position data.

 If you select the interpolation algorithm

0x60C0

= "-11: Optimized mode 1", the

feedforward control values are generated from the interpolation process.

Parameter

Object

Information

C02640

0x55AF

Homing mode

C02641

0x60FB/7

Drive behaviour after setting the home position

C02642

0x607C

Home position

C02644

0x6099/1

Speed 1

C02645

0x609A/1

Acceleration 1

C02646

0x6099/2

Speed 2

C02647

0x609A/2

Acceleration 2

C02651

C055A4

TP configuration

Parameter

Object

Information

C03630

0x60C0

Selection of the interpolation algorithm

C03637

0x60C2/1

Adaptation of interpolation cycle time to communication cycle time

C03638

0x60C2/2

0x60C2/1

: ip time units

0x60C2/2

: ip time index

Interpolation cycle time s

[ ]

ip time units 10

ip time index

s

[ ]

=