EDS94TA11010xxxx EN 1.2 - 03/2010
L
189
9400 Technology applications | CiA402 device profile
Step-by-step commissioning
Settings for "Homing mode"
4.4
Settings for "Homing mode"
For "Homing mode" the following parameters must be set:
4.5
Settings for "Interpolated position mode"
For the "Interpolated position mode" the following parameters must be set:
[4-2]
Definition of the interpolation cycle time
4.6
Speed feedforward control
The source for the speed feedforward control can be selected in C02680 (CiA402 object
0x5587).
The following options are available:
– The source for feedforward control is the
object (target velocity).
– The value for the feedforward control is derived from the position data.
If you select the interpolation algorithm
= "-11: Optimized mode 1", the
feedforward control values are generated from the interpolation process.
Parameter
Object
Information
C02640
0x55AF
Homing mode
C02641
Drive behaviour after setting the home position
C02642
Home position
C02644
Speed 1
C02645
Acceleration 1
C02646
Speed 2
C02647
Acceleration 2
C02651
C055A4
TP configuration
Parameter
Object
Information
Selection of the interpolation algorithm
Adaptation of interpolation cycle time to communication cycle time
: ip time units
: ip time index
Interpolation cycle time s
[ ]
ip time units 10
ip time index
s
[ ]
⋅
=