0x6060, 0x6061, 0x6085 – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 45: Parameter setting & configuration device control

EDS94TA11010xxxx EN 1.2 - 03/2010
L
45
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Device control
0x6060 - Mode of operation
0x6061 - Mode of operation display
0x6085 - Quick stop deceleration
Index | Name:
0x6060 | Mode of operation
Data type: INTEGER_8
Selection of operating mode.
• The current operating mode is displayed in
Selection list
(Lenze setting printed in bold)
Information
0 No mode
Standstill
6 Homing mode
7 Interpolated position mode
8 Cyclic synchronous position mode
Cyclic synchronous position mode
9 Cyclic synchronous velocity mode
Cyclic synchronous velocity mode
10 Cyclic synchronous torque mode
Cyclic synchronous torque mode
;
Read access ; Write access CINH PLC-STOP ; PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6061 | Mode of operation display
Data type: INTEGER_8
Display of the current mode of operation.
• The mode of operation is selected in
.
Selection list
(display only)
Information
0 No mode
Standstill
6 Homing mode
7 Interpolated position mode
8 Cyclic synchronous position mode
Cyclic synchronous position mode
9 Cyclic synchronous velocity mode
Cyclic synchronous velocity mode
10 Cyclic synchronous torque mode
Cyclic synchronous torque mode
;
Read access Write access CINH PLC-STOP PDO_MAP_RX ; PDO_MAP_TX
Index | Name:
0x6085 | Quick stop deceleration
Data type: UNSIGNED_32
Code: C00105
Time between quick stop activation and standstill plus relative S-ramp time (C00106).
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.999 0.000 s
;
Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX Scaling factor: 1000